Characteristics of Air Filter Products

Note:

  • B filter element can be cleared with ultrasonic bath or with back flushing. Intervals of cleaning depends of application.
  • If necessary replace filter element with new one.
  • Filter elements ’’A, A2, H2’’, must be changed periodically to suit application, but at least every 6 months.
  • Activated carbon filters must not operate in oil saturated conditions.
Correction Factors
Operating Pressure [bar] 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Operating Pressure [psi] 29 44 58 72 87 100 115 130 145 160 174 189 203 218 232
Correction Factor 0,38 0,50 0,63 0,75 0,88 1 1,13 1,25 1,38 1,50 1,63 1,75 1,88 2,00 2,13
Specifications are subject to change without prior notice due to remodeling of products, etc.

Standard specification of Air filters

Filter Housing Pipe size Max Oper.
Pressure
Flow rate
@ 7 bar(g), 20°C
Dimension
( mm )
Mass Filter
Element
Type
Size Inch Bar /PSI Nm³/h SCFM A B C D Kg
AF 0056 3/8 16 /232 60 35 187 88 20 60 0.7 06050
AF 0076 1/2 16 /232 78 46 187 88 20 60 0.7 07050
AF 0106 3/4 16 /232 120 71 257 88 20 80 0.8 14050
AF 0186 1 16 /232 198 117 263 125 32 100 1.8 12075
AF 0306 1 16 /232 335 197 363 125 32 120 2.5 22075
AF 0476 1 1/2 16 /232 510 300 461 125 32 140 2.5 32075
AF 0706 1 1/2 16 /232 780 459 640 125 32 160 3.2 50075
AF 0946 2 16 /232 1000 589 684 163 43 520 3.2 51090
AF 1506 2 16 /232 1500 883 935 163 43 770 43 76090
AF 1756 2 1/2 16 /232 1680 989 935 163 43 770 43 76090
AF 2006 3 16 /232 2160 1271 795 240 59 630 59 51140
AF 2406 3 16 /232 2760 1625 1000 240 59 780 59 75140
Specifications are subject to change without prior notice due to remodeling of products, etc.